Hammond 1414PHI6LP - Type 12 Mild Steel Junction Box, 1414 PH SeriesStandards UL 508 Type 12, 13 CSA Type 12, 13 Complies with NEMA Type 12 and 13 JIC EGP-1-1967 unless marked IEC 60529, IP54Application Designed for use as instrument enclosures, electric, hydraulic or pneumatic control housings, electrical junction boxes or terminal wiring enclosures Provides a degree of protection from falling dirt, dust, oil and waterConstruction Smooth, continuously welded seams without knockouts, cutouts or holes Welded brackets provide for enclosure mounting Continuously hinged cover is secured with stainless steel clamps and plated steel screws Seamless poured-in place gasket Models larger than 4 x 4 include a removable 14 gauge inner panel Internal threaded weld studs are provided for mounting inner panels A bonding stud is provided on the door and a grounding stud is provided in the enclosureFinish Cover and enclosure are phosphatized and finished in ANSI 61 gray recoatable powder coating Removable inner panel is finished in white powder coating
Hammond EJ12108S16 Type 4X Stainless Steel Junction Box, Eclipse Junior Smooth, continuously welded seams without knockouts, cutouts, or holes Formed lip on enclosure to exclude flowing liquids and contaminants 14 gauge welded brackets provide for enclosure mounting Continuously hinged cover has stainless steel hinges and provides 180degrees- openingApplication Designed for use as instrument enclosures, electric, hydraulic or pneumatic control housings, electrical junction boxes or terminal wiring enclosures Provides protection where equipment may be hosed down or otherwise be very wet, or in specific applications where corrosion may be a problem For high temperature applications, a gasket retainer may be required, please refer to factoryConstruction Body and cover are formed from 16 guage 304 or 316 stainless steel Smooth, continuously welded seams without knockouts, cutouts, or holes Formed lip on enclosure to exclude flowing liquids and contaminants 14 gauge welded brackets provide for enclosure mounting Continuously hinged cover has stainless steel hinges and provides 180degrees- opening Door latches feature the added safety of quarter turn slot requiring use of tool for opening Quarter turn latches formed from 316 stainless steel Seamless poured-in place gasket Models larger than 4x4 include a removable 14 gauge galvanized inner panel Tapped studs are provided for mounting inner panels A bonding stud is provided on the door and a grounding stud is provided on the enclosure Grounding and panel mounting hardware providedFinish Cover and enclosure are natural stainless steel with a smooth brushed finish Removable inner panel is unpainted galvanized steelUnits shown: inch 304 S.S. 316 S.S. Overall Dimensions Panel Size Ship Wt. Part No. Part No. A B C D E F
Hammond EJ644LG - Type 4 Mild Steel Junction Box, Eclipse Junior Series Hammond Type 4 Mild Steel Junction Box, Eclipse Junior Series x Standards UL 508 Type 3R, 4, 12 and 13 CSA Type 3R, 4, 12 and 13 Complies with NEMA Type 3R, 4, 12 and 13 IEC 60529, IP66Application Designed for use as instrument enclosures, electric, hydraulic or pneumatic control housings, electrical junction boxes or terminal wiring enclosures Provides a degree of protection from falling dirt, dust, oil and waterConstruction Body formed from 16 gauge or 14 gauge steel. Covers are formed from 14 gauge steel Smooth, continuously welded seams without knockouts, cutouts or holes Welded brackets provide for enclosure mounting Lift off cover is secured with stainless steel clamps and plated steel screws and retained with a plated chain when open Seamless poured-in place gasket Models larger than 4 x 4 include a removable 14 gauge inner panel Internal threaded weld studs are provided for mounting inner panels A bonding stud is provided on the door and a grounding stud is provided on the enclosureFinish Cover and enclosure are phosphatized and finished in ANSI 61 gray recoatable powder coating Removable inner panel is finished in white powder coatingx
Hammond EJ884S16 Type 4X Stainless Steel Junction Box, Eclipse JuniorxStandards UL 508A Type 3R, 4, 4X, 12, and 13 CSA Type 3R, 4, 4X, 12, and 13 Complies with: NEMA Type 3R, 4, 4X, 12 and 13 JIC EGP-1-1967 IEC 60529, IP66Application Designed for use as instrument enclosures, electric, hydraulic or pneumatic control housings, electrical junction boxes or terminal wiring enclosures Provides protection where equipment may be hosed down or otherwise be very wet, or in specific applications where corrosion may be a problem For high temperature applications, a gasket retainer may be required, please refer to factoryConstruction Body and cover are formed from 16 guage 304 or 316 stainless steel Smooth, continuously welded seams without knockouts, cutouts, or holes Formed lip on enclosure to exclude flowing liquids and contaminants 14 gauge welded brackets provide for enclosure mounting Continuously hinged cover has stainless steel hinges and provides 180degrees- opening Door latches feature the added safety of quarter turn slot requiring use of tool for opening Quarter turn latches formed from 316 stainless steel Seamless poured-in place gasket Models larger than 4x4 include a removable 14 gauge galvanized inner panel Tapped studs are provided for mounting inner panels A bonding stud is provided on the door and a grounding stud is provided on the enclosure Grounding and panel mounting hardware providedFinish Cover and enclosure are natural stainless steel with a smooth brushed finish Removable inner panel is unpainted galvanized steelxUnits shown: inch 304 S.S. 316 S.S. Overall Dimensions Panel Size Ship Wt. Part No. Part No. A B C D E F G H J lbs EJ443SS EJ443S16 4.00
Hammond EN4DSC24228GY Type 4 Mild Steel Wallmount Disconnect Enclosure, EclipsexStandards UL 508A Type 3R, 4 CSA Type 3R, 4 Complies with: NEMA Type 3R, 4, 12 and 13 JIC EGP-1-1967 IEC 60529, IP66 Appropriate components are required to maintain these standardsApplication Designed to house the following safety disconnect equipment: ABB Controls flange mounted variable depth operating mechanisms for disconnect switches and circuit breakers. Cable version for circuit breakers also available. Allen Bradley 1494V variable depth flange mounted disconnect switches and circuit breaker operators NEMA 4 rated. Will not accept Allen Bradley 1494F disconnect switches, 1494D circuit breaker operators or 1494V-R1, -R2, or -W2 operating handles). Cutler Hammer C361 variable depth flange mounted disconnect switches and C371 circuit breaker operators. Also Flex-Shaft handle mechanisms for circuit breakers. Use Cutler Hammer NEMA 4X rated operating handles to maintain NEMA 4X integrity. Siemens I-T-E Max-Flex flange mounted variable depth handles for disconnect switch and circuit breakers. Use handle for NEMA 4 rating. General Electric Type STDA flange handles and variable depth operating mechanisms for disconnect switches and circuit breakers. AlsoSpectraFlex cable operators for circuit breakers. Square D Class 9422 disconnect switches with flange mounted variable depth operating mechanisms or cable mechanisms and Class 9422 flange mounted variable depth operating mechanism or cable mechanisms for circuit breakers. SN4SS enclosures will not accept Square D Class 9422 bracket-mounted disconnect devices, 9422TG1 or TG2 devices.Construction Formed 14 or 16 gauge steel Continuously welded seams Larger sizes include door stiffeners Formed lip on door and enclosure exclude flowing liquids and contaminants Cutouts and holes are provided to s
Hammond HJ12146HLP - Type 4, 12 Mild Steel Junction Box, HJ H Series Hammond Type 4, 12 Mild Steel Junction Box, HJ H Series x Standards UL 508 Type 3R, 4, 12 and 13 CSA Type 3R, 4, 12 and 13 Complies with NEMA Type 3R, 4, 12 and 13 JIC EGP-1-1967 unless marked IEC 60529, IP66Application Designed for use as instrument enclosures, electric, hydraulic or pneumatic control housings, electrical junction boxes or terminal wiring enclosures Provides protection where equipment may be hosed down or otherwise be very wet, or in outdoor applications for full weather protectionConstruction Body formed from 16 or 14 gauge steel. Covers are formed from 14 gauge steel. Smooth, continuously welded seams without knockouts, cutouts or holes Welded brackets provide for enclosure mounting Continuous hinged cover is secured with stainless steel clamps and screws Stainless steel continuous hinge on door may be removed by pulling the stainless steel hinge pin Seamless poured-in place gasket Internal threaded weld studs are provided for mounting inner panels A bonding stud is provided on the door and a grounding stud is provided in the enclosureFinish Cover and enclosure are phosphatized, finished in re-coatable smooth ANSI 61 gray powder coatingx Mounting Centers Cover Dimensions Gauge Opt. Panel Opt. Panel Ship Wt. Part No. A B C G H M N Body Door Part No. 2 Size (lbs) HJ443HLP 4.00 4.00 3.00 4.75 2.00 4.31 4.31 16 14 - - - HJ643HLP 6.00 4.00
Hammond HJ664LP - Type 4, 12 Mild Steel Junction Box, HJ Series Hammond Type 4, 12 Mild Steel Junction Box, HJ Series x Standards UL 508 Type 3R, 4, 12 and 13 CSA Type 3R, 4, 12 and 13 Complies with NEMA Type 3R, 4, 12 and 13 JIC EGP-1-1967 unless marked IEC 60529, IP66Application Designed for use as instrument enclosures, electric, hydraulic or pneumatic control housings, electrical junction boxes or terminal wiring enclosures Provides a degree of protection from falling dirt, dust, oil and waterConstruction Body formed from 16 gauge or 14 gauge steel. Covers are formed from 14 gauge steel Smooth, continuously welded seams without knockouts, cutouts or holes Welded brackets provide for enclosure mounting Lift off cover is secured with stainless steel clamps and stainless steel screws and retained with a stainless steel chain when open Seamless poured-in place gasket Internal threaded weld studs are provided for mounting inner panels A bonding stud is provided on the door and a grounding stud is provided on the enclosureFinish Cover and enclosure are phosphatized and finished in ANSI 61 gray re-coatable powder coatingx Overall Dimensions Mounting Centers Cover Dimensions Gauge Opt. Inner Panel Opt. Panel Ship Wt. Part No. A B C G H M N Body Door Part No. Size (lbs) HJ643LP 6.00 4.00 3.00 6.75 2.00 6.31 4.31 16 14 14R0503 4.88 2.88 2 HJ863LP 8.00 6.00 3.50 8.75 4.00
Hammond ST302412SS Type 4X Stainless Steel Wallmount Enclosure w/ Sloped Top, ST SSxStandards UL 508A Type 3R, 4, 4X and 12 CSA Type 3R, 4, 4X and 12 Complies with NEMA 3R, 4, 4X, 12 and 13 IEC 60529, IP 66Application Designed to enclose electrical and/or electronic equipment and protect against harsh, industrial environments for wallmount applications Sloped top prevents water from resting on top as well as providing potential for controls mounting Impressive styling features like hidden hinges and attractive latching systems make the Eclipse a suitable addition to any high-tech equipment installation A wide range of sizes and practical accessories make this product line a complete packageConstruction Formed 304 stainless steel Continuously welded seams ground smooth Door stiffeners are provided where required for increased strength and rigidity - designed to also permit additional mounting options Formed lip on enclosure to exclude flowing liquids and contaminants Door latches feature the added safety of quarter turn slot requiring use of tool for opening Doors may be easily removed for modifications and are interchangeable Seamless poured-in place gasket Collar studs provided for mounting inner panel Includes hardware kit with panel mounting nuts and sealing washers for wall mounting holes Bonding stud provided on door and grounding stud installed in enclosure Hinges are 304 stainless Stainless steel hinge pins and quarter turns Door alignment guide provided on 36 wide enclosuresFinish Cover and enclosure are natural stainless steel with a smooth brushed finishxUnits shown: inch. Part No. Overall Dimensions Door/Body Opt. Panel Latch Hinge A1 A2 B C G Gauge Part No. Qty Qty ST161208SS 16
Hand Operated Drum Pump, Action Type Rotary, Pump Body Material Aluminum, Wetted Materials Aluminum, Zinc, Steel, Viton, PVC Nitrile, Seal Material Viton, Discharge Tubing Material Steel, Hose Material PVC Nitrile, For Use On 15 to 55 gal Drums, Max. Temp. 140 Degrees F, Ounces per Stroke 7 oz., Max. Viscosity 5000 SSU, Inlet Size 1", Outlet Size 3/4", Discharge Tube Outlet ID Size 21/32", Discharge Tube Outlet OD Size 3/4", Discharge Tube Length 5- 1/2", Hose Length 6 ft., Suction Tube Length 41", Suction Tube Outlet O.D. Size 1-1/4", Suction Tube Type 3-Piece Rigid Pipe, Overall Length 46- 1/4", Adapter Type 2" Bung, Adapter Material Cast Iron, Application For Use in Industrial and Automotive Applications with Gasoline, Diesel Fuel, Kerosene and Lubricating Oils Up to SAE 60, Features Handle Comes with A Security Locking Latch, Includes Pump Body, Suction Tube, 2" Bung, Curved Metal Spout, Delivery Hose with Metal Nozzle, Manufacturers Warranty Length 1 yr.WARNING: California ResidentsThis product can expose you to chemicals including Styrene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Hand Scrub Brush, Bristle Color White, Trim Length 2-1/2 In., Bristle Material Polyester, Brush Bristle Firmness Soft, Brush Length 8 In., Brush Width 1 In., Overall Length 13 In., Handle Length 5 In., Handle Material Plastic, Handle Color White, Chemical Resistant Yes, Temperature Resistant Yes, Acid Resistant Yes, Color Coding System Yes, FDA Compliant Yes
Hand tap has plug type and forming style, high speed steel-cobalt with TiCN finish, size M2.6, pitch 0.45 mm, metric, 2.5P, pitch diameter limits D3, shank diameter 2.500". Cobalt and powdered metal thread forming taps create strong threads without creating chips and are recommended for forming internal threads in aluminum as well as carbon, alloy, die, and stainless steels.