{
  "product": {
    "mpn": "B00V04I7G4",
    "manufacturer": "OMRON",
    "brand": "OMRON",
    "title": "Cylinder type sensing head size] M18 <br>[Type] Shielded <br>[Sensing method] Inductive type <br>[Sensing distance] 7mm -10% to +10% <br>[Setting distance] 0 to 5.6 mm <br>[Differential distance] 10% Max. of sensing distance <br>[Sensing object] Ferrous metal (Sensitivity lowers with non-ferrous metals.) <br>[Standard sensing object] Iron 18*18*1mm <br>[Response frequency] DC: 0.5 kHz (average) <br>[Power supply voltage] 12 to 24 VDC ripple(p-p) :10% Max. <br>[Operating voltage range] 10 to 30 VDC <br>[Leakage current] 0.8 mA Max. <br>[Control output (Output type)] DC 2-wire models with polarity <br>[Control outpu (Switching capacity)] 3 to 100mA <br>[Indicator] Operation indicator(red), Operation setting indicator(green) <br>[Operation mode] NO <br>[Self-diagnostic output] Diagnostic output 50mA <br>[Self-diagnostic output delay] 0.3 to 1s <br>[Protective circuit] Surge suppressor <br>Output short-cut protection <br>[Ambient temperature] Operating: -25 to 70 CEL <br>Storage: -40 to 85CEL(with no icing or condensation) <br>[Ambient humidity] 35 to 95 %RH <br>[Voltage influence] +/- 1% Max. of sensing distance in rated voltage range +/- 15%. (As the basis for sensing distance at standard power voltage) <br>[Degree of protection] IEC60529: IP67 <br>Company standard: Oil-proof <br>[Applicable standard (EC Directive (Low Voltage Directive) )] EN60947-1,EN60947-5-2 <br>[Applicable standard (EC Directive (EMC))] EMI: EN60947-5-2 <br>Emission Enclosure: CISPR11 Group 1 class A <br>EMS: EN60947-5-2 <br>Immunity ESD: IEC61000-4-2 <br>Immunity RF-interference: IEC61000-4-3 <br>Immunity Conducted Disturbance: IEC61000-4-6 <br>Immunity Burst: IEC61000-4-4 <br>CE marking: Equipped <br>[Applicable standard (CCC mark)] Not equipped <br>[Connection method] Pre-wired models (Cable length: 5 m) <br>[Weight (Packed state)] approx. 265 g<br><br><br>(1)",
    "description": "",
    "attributes": {
      "Brand name": "OMRON",
      "Manufacturer name": "OMRON",
      "Manufacturer": "OMRON",
      "Attribute00": "B00V04I7G4",
      "Attribute01": "OMRON",
      "AttributeKey00": "ASIN",
      "AttributeKey01": "Manufacturer",
      "DimensionUnit": "inches",
      "dataSource": "amazonScraper",
      "height": "5.6",
      "length": "1",
      "moq": "1",
      "multiple": "1",
      "qtyInStock": "0",
      "SKU": "B00V04I7G4",
      "snippet": "Cylinder type sensing head size] M18 <br>[Type] Shielded <br>[Sensing method] Inductive type <br>[Sensing distance] 7mm -10% to +10% <br>[Setting distance] 0 to 5.6 mm <br>[Differential distance] 10% Max. of sensing distance <br>[Sensing object] Ferrous metal (Sensitivity lowers with non-ferrous metals.) <br>[Standard sensing object] Iron 18*18*1mm <br>[Response frequency] DC: 0.5 kHz (average) <br>[Power supply voltage] 12 to 24 VDC ripple(p-p) :10% Max. <br>[Operating voltage range] 10 to 30 VDC <br>[Leakage current] 0.8 mA Max. <br>[Control output (Output type)] DC 2-wire models with polarity <br>[Control outpu (Switching capacity)] 3 to 100mA <br>[Indicator] Operation indicator(red), Operation setting indicator(green) <br>[Operation mode] NO <br>[Self-diagnostic output] Diagnostic output 50mA <br>[Self-diagnostic output delay] 0.3 to 1s <br>[Protective circuit] Surge suppressor <br>Output short-cut protection <br>[Ambient temperature] Operating: -25 to 70 CEL <br>Storage: -40 to 85CEL(with no icing or condensation) <br>[Ambient humidity] 35 to 95 %RH <br>[Voltage influence] +/- 1% Max. of sensing distance in rated voltage range +/- 15%. (As the basis for sensing distance at standard power voltage) <br>[Degree of protection] IEC60529: IP67 <br>Company standard: Oil-proof <br>[Applicable standard (EC Directive (Low Voltage Directive) )] EN60947-1,EN60947-5-2 <br>[Applicable standard (EC Directive (EMC))] EMI: EN60947-5-2 <br>Emission Enclosure: CISPR11 Group 1 class A <br>EMS: EN60947-5-2 <br>Immunity ESD: IEC61000-4-2 <br>Immunity RF-interference: IEC61000-4-3 <br>Immunity Conducted Disturbance: IEC61000-4-6 <br>Immunity Burst: IEC61000-4-4 <br>CE marking: Equipped <br>[Applicable standard (CCC mark)] Not equipped <br>[Connection method] Pre-wired models (Cable length: 5 m) <br>[Weight (Packed state)] approx. 265 g<br><br><br>(1)",
      "tierMinQty1": "1",
      "width": "5.2"
    },
    "images": [],
    "distributors": [
      {
        "name": "Amazon",
        "sku": "B00V04I7G4",
        "url": "https://www.amazon.com/dp/B00V04I7G4",
        "pricing": [],
        "stock": {
          "available": false,
          "quantity": null,
          "lead_time_days": null
        },
        "moq": 1,
        "multiple": 1
      }
    ],
    "amazon": {
      "available": false,
      "products": []
    },
    "metadata": {
      "generated_date": "2026-01-01",
      "last_updated": "2026-01-01",
      "data_sources": [
        "Amazon"
      ],
      "completeness": 0.65,
      "version": "1.1"
    }
  }
}